Device / Run / AccessRightsOfBAC Value
			
			
				
					Specifies the behavior of the reader if a BALTECH AdrCard 
					(BAC) or an NFC device enabled for bus address setup is 
					presented.
				
				
					When setting a bus address via NFC, also set the 
					configuration value 
					RequiresBusAddress to ensure a correct workflow of the 
					upload software tool.
				
			 
			
				
					Properties
				
				
					- 
						Value ID: 0x0202/0x12
					
 
					- 
						Default value:
						
							EnabledOnTamper
						
					
 
				
			 
			
				
					Format
				
				
					
						
						
						
						
					
					
						| 
							Name
						 | 
						
							Type/Size
						 | 
						
							Description
						 | 
					
					
						| 
							-
						 | 
						
							Enumeration (8 bits)
						 | 
						
							Values:
							
								- 
									
										Disabled (0x00)
									
									
										Disables BALTECH AdrCards permanently
									 
								 
								- 
									
										ReadOnly (0x01)
									
									
										The reader will signal the bus address 
										via beeper when a BALTECH AdrCard is 
										presented. It is not possible to change 
										the address using the AdrCard.
									 
								 
								- 
									
										EnabledOnTamper (0x02)
									
									
										The bus address can always be 
										retrieved. Changing the bus address via 
										BALTECH AdrCard is possible as long as 
										no Config Security Code is set or when 
										the reader housing (i.e. the tamper 
										switch) is open. This is the default 
										setting if the value is not set.
									 
								 
								- 
									
										Enabled (0x03)
									
									
										There are no restrictions at all. The 
										bus address can always be retrieved and 
										changed using BALTECH AdrCard.
									 
								 
							 
						 |