Device / Run / AccessRightsOfBAC Value
Specifies the behavior of the reader if a BALTECH AdrCard
(BAC) or an NFC device enabled for bus address setup is
presented.
When setting a bus address via NFC, also set the
configuration value
RequiresBusAddress to ensure a correct workflow of the
upload software tool.
Properties
-
Value ID: 0x0202/0x12
-
Default value:
EnabledOnTamper
Format
Name
|
Type/Size
|
Description
|
-
|
Enumeration (8 bits)
|
Values:
-
Disabled (0x00)
Disables BALTECH AdrCards permanently
-
ReadOnly (0x01)
The reader will signal the bus address
via beeper when a BALTECH AdrCard is
presented. It is not possible to change
the address using the AdrCard.
-
EnabledOnTamper (0x02)
The bus address can always be
retrieved. Changing the bus address via
BALTECH AdrCard is possible as long as
no Config Security Code is set or when
the reader housing (i.e. the tamper
switch) is open. This is the default
setting if the value is not set.
-
Enabled (0x03)
There are no restrictions at all. The
bus address can always be retrieved and
changed using BALTECH AdrCard.
|